Cabinet
is made of durable plastic. The heat exchanger body is available in lengths from 330 to 600 mm. This section contains a counter-current heat exchanger. The ECOROOM heat recovery unit is available in two versions - DN 100 and DN 150.
Fans
The unit is equipped with two radial fans with DC motors and is designed for continuous operation. IPX4 protection.
Recuperation
The unit is equipped with a counter-current heat exchanger. The heat exchanger is easily accessible by opening the top cover of the unit. Recovery efficiency up to 75%. The unit is equipped with automatic frost protection.
Regulation
Automatic stepless speed control based on a unique humidity detection system. This regulation ensures optimum room air quality. The unit includes automatic summer operation and a pull switch for short-term power boost "BOOST".
Mounting
On the wall using four mounting screws. The unit can only be installed in the horizontal axis of the heat exchanger body with a minimum 1% outward slope. The long connection extension (330-600 mm) includes a counter-current heat exchanger. For the selection of the extension, the wall width is the decisive criterion. The unique design of the unit ensures easy maintenance and cleaning. The ECOROOM unit is suitable for use when replacing an existing fan without the need for extensive installation preparation.
Options
ECOROOM xxx/yy
- xxx - DN 100 or DN 150
- yyy - length of wall extension (330, 430, 500 or 600 mm)
Information
When ventilating individual rooms with a fan, the polluted air is extracted and replaced with air from adjacent rooms or drawn in through an opening from the outside. If the air in adjacent rooms is of poor quality, the first solution is not suitable. In the latter case, the space is again cooled. ECOROOM solves these problems and offers a solution where the exhaust air heats the incoming fresh outside air. Fresh outside air is thus brought into the ventilated room, but the room is not cooled.
Highlights
The ECOROOM ventilation unit is the ideal solution for replacing non-functioning, previously installed 100 or 150 mm diameter fans in existing installations (without the need for additional building modifications and wiring).
Instructions
- Frost protection as standard
- automatic switchover to summer operation
- intelligent control depending on relative humidity
- option of pull switch control
- shutdown in case of opening of the front of the cabinet (magnetic switch)
Included in the delivery is a kit for conversion to safe 12 V.